KEY FEATURES
Up to 128 Sensors
Complete Data Logging Package included in Software
Digital and Bar Graph Displays are standard
Print on demand or user configurable
Easy To Install
​
Maximum, Minimum and Time Weighted Average displayed
Descrivi l'immagine.
Analygas® Systems Model 43 is designed
for the specific detection of Carbon Dioxide.
​
The Model 43 can be installed in conjunction with our Model 40 or 41 multipoint units.
Alternatively, it can interface with a computer
or other data acquisition system.
KEY FEATURES
Highly Specific
Non-dispersive Infrared Detector
Rugged steel enclosure
​
Compact
​
4-20mA or 0-1V Output
​
Detection Range up to 100% Carbon Dioxide
SPECIFICATIONS
Infrared Detector
​
Single Sensing Point
​
24 VDC Input, 200m
​
4-20mA or 0-1V Output
​
Operating Temperatur -10ºC to 40ºC
14ºF to 104ºF
Air being sampled, enters through a fitting at the bottom of the unit, diffuses through the sensor and
is exhausted at the top.
​
The signal output is a linear function of gas concentration. Because of its simplicity and versatility, the Model 43 can interface with a computer or other data acquisition system.
Alternatively, it can be used in conjunction with Analygas Systems Model 40 or 41 multipoint units.
While ideal for use as an indoor air quality monitor, this low maintenance instrument is equally at home in food processing facilities, bottling plants, breweries, etc.
Analygas® Systems Model Model 43 is a wall mounted gas monitor for use in non-hazardous indoor locations.
​
It utilizes non-dispersive infrared technology
to specifically detect Carbon Dioxide.
The central component is an Analygas Systems designed infrared sensor assembly that can be configured to detect up to 100% of the target gas.
​
Housed in a rugged steel enclosure, the Model 43
is easily installed on vertical surfaces.
Air being sampled, enters through a fitting at the bottom of the unit, diffuses through the sensor and
is exhausted at the top.
​
The signal output is a linear function of gas concentration. Because of its simplicity and versatility, the Model 43 can interface with a computer or other data acquisition system.
Alternatively, it can be used in conjunction with Analygas Systems Model 40 or 41 multipoint units.
While ideal for use as an indoor air quality monitor, this low maintenance instrument is equally at home in food processing facilities, bottling plants, breweries, etc.